Application Scenarios
Ultrasonic flow meters are widely used in water conservancy projects (reservoir and river flow monitoring), municipal water supply and drainage, industrial circulating water systems, and environmental protection sewage treatment.
1. Operating Parameters
Parameter | Description |
Supply Voltage | DC 7~28V |
Current (12V Power Supply) | Average current is about 60mA (5—100mA) during normal operation |
Operating Temperature | -40~85°C |
Waterproof Rating | IP68 |
Transmission Type | Ultrasonic |
Communication Interface | RS-485 |
Communication Protocol | MODBUS-RTU |
1.2 Measurement Parameters
Parameter | Description |
Velocity Measurement Range | 0~10m/s |
Velocity Measurement Accuracy | 0.3%FS |
Resolution | 0.01m/s |
Maximum Water Depth | 10m |
Start-up Time | <3s |
Measurement Direction | Bidirectional/Unidirectional |
1.3 Wiring
The number of cable cores is subject to the actual goods, and the definitions of cables with different core numbers are different:
Four-core Cable:
Pin No. | Color | Definition |
1 | Red | Power Positive |
2 | Black | Power Ground |
3 | Blue | RS485_A(+) |
4 | Yellow | RS485_B(-) |
1.4 Communication Interface
1.4.1 RS485 Interface
When communicating with RS485 interface, the basic settings are as follows:
Baud Rate | 9600 (default, configurable) |
Parity Bit | None |
Data Bits | 8 |
Stop Bits | 1 |
2. Communication Protocol
2.1 MODBUS Protocol
2.1.1 RTU Frame Structure
In RTU mode, a new message always starts with a silent period of at least 3.5 characters, followed by the first field: the address field. The entire frame of information must be transmitted as a continuous data stream. If there is an interval of more than 1.5 characters before the end of the information, an error will occur.
Start | Device Address | Function Code | Data | CRC Check | End |
T1-T2-T3-T4 | 8Bit | 8Bit | n 8Bits | 16 Bit | T1-T2-T3-T4 |
Address Field: The valid address range of the slave (target address) is 1~247, supporting broadcast send-receive address 0xFF and broadcast receive-only address 0xFE. When using the broadcast address, ensure that only one sensor is connected; otherwise, it will cause data errors or hardware damage.
Function Field: Valid codes are 1~255. The ultrasonic flow meter supports 0x03, 0x06, and 0x10 function codes.
Data Field: The data field consists of multiple groups of such data—two hexadecimal numbers as a group, ranging from 00~FF.
CRC Check Code: After CRC generation, the low byte comes first and the high byte comes after.
T1, T2, T3, T4 represent the transmission time length of each byte, totaling four byte transmission delay times.
9600, 8, N, 1; (The upper computer serial port number ranges from 1 to 20 to facilitate communication with USB-to-serial cables extended by USB-HUB).
RS485; (Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential, twisted pair;
Data Rules: The high bit of the data area comes first;
CRC Check Rule: When the CRC result is placed in the information frame, the low bit comes first.
2.1.2 Ultrasonic Flow Meter Register Variable Status Table
U16: Unsigned 16-bit integer
No. | Register Address | Function | Unit | Remarks |
1 | 00H | Device Temperature, signed number, scale factor +100 | 0.01°C | Invalid |
2 | 01H | Instantaneous Velocity | mm/s | For testing |
3 | 02H | Average Velocity | mm/s | Customers should use this result |
4 | 03H | Reserved | ||
5 | 04H | Flow Direction | 1: Downstream | |
6 | 05H | Installation Angle, scale factor +100 | 0.01° | Angle with horizontal plane |
7 | 06H | Device Voltage | mV | Device Voltage |
8 | 07H | Jump Filter Status | 1: Jump | |
9 | 08H | Instantaneous Flow Rate (m³/S) | Independent flow register, exists independently of the previous registers and is discontinuous | |
10 | 09H | Water Depth | cm | |
11 | 0AH | Midline Velocity | mm/S | |
12 | 0BH | Low Power Consumption Setting | 0x001: Low power consumption; | |
13 | 0CH | Baud Rate | 0x001: 9600; | |
14 | 0DH | Gain Value | 0x0000: Auto gain; others are set gain values | |
15 | 0EH | Time Domain Threshold | ||
16 | 0FH | Frequency Domain Threshold | ||
17 | A0H | Address |