Operating Parameters
Parameter | Description |
Supply Voltage | DC 7~28V |
Current (12V Power Supply) | Average current is about 60mA (5—100mA) during normal operation |
Operating Temperature | -40~85°C |
Waterproof Rating | IP68 |
Transmission Frequency | Adjustable 25.75~26GHz |
Communication Interface | RS-485 |
Communication Protocol | MODBUS-RTU |
2. Measurement Parameters
Parameter | Description |
Current Measurement Range | 0~15m/s |
Current Measurement Accuracy | ±0.02m/s |
Resolution | 0.01m/s |
Effective Distance | 0.2~30m |
Start-up Time | <3s |
Measurement Direction | Bidirectional |
Automatic Angle Correction | 30°~60° |
3. Wiring Instructions
Four-core Cable Definition:
Pin No. | Color | Definition |
1 | Red | Power Positive (+) |
2 | Blue | Power Ground (-) |
3 | Brown | RS485_A(+) |
4 | Yellow | RS485_B(-) |
Installation Angle Requirement: The installation angle of the current meter should be 45~60 degrees, which refers to the angle between the antenna beam direction of the current meter and the horizontal plane. For river channels with uneven water flow, small angles are prone to data jump. A larger installation angle can better suppress rainfall interference and improve signal quality; it is recommended to set the installation angle to about 60 degrees. After installation, the angle can be read through communication to ensure the accuracy of measured data.

4. Communication Interface
4.1 RS485 Interface
Basic communication settings for RS485 interface are as follows:
Parameter | Setting |
Baud Rate | 9600 (default, configurable) |
Parity Bit | None |
Data Bits | 8 |
Stop Bits | 1 |
5. MODBUS Protocol
5.1 RTU Frame Structure
In RTU mode, a new message must start with a silent period of at least 3.5 character times, followed by the first field: the address field. The entire message frame must be transmitted as a continuous data stream. If there is an interval exceeding 1.5 character times before the end of the message, a communication error will occur.
Start | Device Address | Function Code | Data | CRC Check | End |
T1-T2-T3-T4 | 8Bit | 8Bit | n 8Bits | 16 Bit | T1-T2-T3-T4 |
Field Explanation:
• Address Field: The valid address range of the slave (target device) is 1~247, supporting broadcast send-receive address 0xFF and broadcast receive-only address 0xFE. When using the broadcast address, ensure that only one sensor is connected; otherwise, data errors or hardware damage may occur.
• Function Field: Valid function code range is 1~255. The radar current meter supports function codes 0x03, 0x06, and 0x10.
• Data Field: Composed of multiple groups of hexadecimal data, with two hexadecimal digits as one group, ranging from 00~FF.
• CRC Check Code: After CRC calculation, the low byte is transmitted first, and the high byte is transmitted later.
• T1-T2-T3-T4: Represent the transmission time of each byte, totaling four byte transmission delay times.
Supplementary Communication Specifications:
• Baud Rate/Parity/Data Bits/Stop Bits: 9600/None/8/1 (The upper computer serial port number ranges from 1 to 20, facilitating communication with USB-to-serial cables extended by USB-HUB).
• RS485 Communication: Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential signal, twisted pair recommended.
• Data Rule: The high bit of the data area is transmitted first.
• CRC Check Rule: When the CRC result is placed in the message frame, the low byte comes first.
5.2 Radar Current Meter Register Table
Note: U16 = Unsigned 16-bit integer
No. | Register Address | Function Description | Unit | Remarks |
1 | 00H | Device Temperature (signed number, scale factor ×100) | 0.01°C | Invalid |
2 | 01H | Instantaneous Current Velocity | mm/s | For testing |
3 | 02H | Average Current Velocity | mm/s | Recommended for customer use |
4 | 03H | Reserved | - | - |
5 | 04H | Flow Direction | - | 1: Downstream; 2: Upstream |
6 | 05H | Installation Angle (scale factor ×100) | 0.01° | Angle with horizontal plane |
7 | 06H | Device Voltage | mV | Device power supply voltage |
8 | 07H | Jump Filter Status | - | 1: Jump; 0: Normal |
9 | 08H | Instantaneous Flow Rate | m³/S | Independent flow register, discontinuous from previous registers |
10 | 09H | Water Depth | cm | - |
11 | 0AH | Midline Current Velocity | mm/s | - |
12 | 0BH | Low Power Consumption Setting | - | 0x001: Low power consumption; 0x002: Non-low power consumption |
13 | 0CH | Baud Rate Setting | - | 0x001: 9600; 0x002: 115200 |
14 | 0DH | Gain Value | - | 0x0000: Auto gain; Other values: Manual gain |
15 | 0EH | Time Domain Threshold | - | - |
16 | 0FH | Frequency Domain Threshold | - | - |
17 | A0H | Device Address | - | - |