Integrated radar flowmeter

$10000.00
Color silvery white
Weight 4.5kg
measure distance 0~40M
voltage 12V
Click to consult
立即预约
Detail

Operating Parameters

Parameter

Description

Flow Measurement Range

0~20m/s

Flow Measurement Accuracy

±0.02m/s

Resolution

0.01m/s

Effective Distance

40m

Start-up Time

<3s

Measurement Direction

Bidirectional

Automatic Angle Correction

30°~60°

2. Distance Measurement Parameters

Parameter

Description

Distance Measurement Range

40m

Distance Measurement Accuracy

±3mm

Resolution

1mm

Measurement Time

1s

Start-up Time

<3s

3. Power Supply & Environmental Parameters

Four-core Cable Definition:

Parameter

Description

Supply Voltage

DC 7~28V

Current (12V Power Supply)

Operating current is about 200mA

Operating Temperature

-40~85°C

Waterproof Rating

IP68

Transmission Frequency

24~26GHz

Communication Interface

RS-485

Communication Protocol

MODBUS-RTU

Installation Angle Requirement: The installation angle of the current meter should be 45~60 degrees, which refers to the angle between the antenna beam direction of the current meter and the horizontal plane. For river channels with uneven water flow, small angles are prone to data jump. A larger installation angle can better suppress rainfall interference and improve signal quality; it is recommended to set the installation angle to about 60 degrees. After installation, the angle can be read through communication to ensure the accuracy of measured data.

4. Wiring Instructions (1.2 Wiring)

Refer to the cable description according to the actual goods:

Four-core Cable:

Basic communication settings for RS485 interface are as follows:

Pin No.

Color

Definition

1

Red

Power Positive

2

Blue

Power Ground

3

Brown

RS485_A(+)

4

Yellow

RS485_B(-)

5. Communication Interface (1.3 Communication Interface)

Green cable is RS485A(+), yellow cable is RS485B(-).

When communicating with RS485 interface, the basic settings are as follows:

6. Flow Meter Dimensions (1.4 Flow Meter Dimensions)

Specific Dimensions:

Installation at 45 degrees (45-degree installation is recommended when the distance from the water surface is within 5 meters)

60-degree Installation Bracket (choose 60-degree when the distance from the water surface exceeds 5 meters)

Parameter

Setting

Baud Rate

9600 (default)

Parity Bit

None

Data Bits

8

Stop Bits

1

Field Explanation:

• Address Field: The valid address range of the slave (target device) is 1~247, supporting broadcast send-receive address 0xFF and broadcast receive-only address 0xFE. When using the broadcast address, ensure that only one sensor is connected; otherwise, data errors or hardware damage may occur.

• Function Field: Valid function code range is 1~255. The radar current meter supports function codes 0x03, 0x06, and 0x10.

• Data Field: Composed of multiple groups of hexadecimal data, with two hexadecimal digits as one group, ranging from 00~FF.

• CRC Check Code: After CRC calculation, the low byte is transmitted first, and the high byte is transmitted later.

• T1-T2-T3-T4: Represent the transmission time of each byte, totaling four byte transmission delay times.

Supplementary Communication Specifications:

• Baud Rate/Parity/Data Bits/Stop Bits: 9600/None/8/1 (The upper computer serial port number ranges from 1 to 20, facilitating communication with USB-to-serial cables extended by USB-HUB).

• RS485 Communication: Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential signal, twisted pair recommended.

• Data Rule: The high bit of the data area is transmitted first.

• CRC Check Rule: When the CRC result is placed in the message frame, the low byte comes first.

5.2 Radar Current Meter Register Table

Note: U16 = Unsigned 16-bit integer

No.

Register Address

Function Description

Unit

Remarks

1

00H

Device Temperature (signed number, scale factor ×100)

0.01°C

Invalid

2

01H

Instantaneous Current Velocity

mm/s

For testing

3

02H

Average Current Velocity

mm/s

Recommended for customer use

4

03H

Reserved

-

-

5

04H

Flow Direction

-

1: Downstream; 2: Upstream

6

05H

Installation Angle (scale factor ×100)

0.01°

Angle with horizontal plane

7

06H

Device Voltage

mV

Device power supply voltage

8

07H

Jump Filter Status

-

1: Jump; 0: Normal

9

08H

Instantaneous Flow Rate

m³/S

Independent flow register, discontinuous from previous registers

10

09H

Water Depth

cm

-

11

0AH

Midline Current Velocity

mm/s

-

12

0BH

Low Power Consumption Setting

-

0x001: Low power consumption; 0x002: Non-low power consumption

13

0CH

Baud Rate Setting

-

0x001: 9600; 0x002: 115200

14

0DH

Gain Value

-

0x0000: Auto gain; Other values: Manual gain

15

0EH

Time Domain Threshold

-

-

16

0FH

Frequency Domain Threshold

-

-

17

A0H

Device Address

-

-