Technical Parameters
Parameter | Description |
Supply Voltage | DC 7~28V |
Current (12V Power Supply) | 30mA |
Operating Temperature | -20~60°C |
Waterproof Rating | IP65 |
Transmission Type | Ultrasonic |
Communication Interface | RS-485 |
Communication Protocol | MODBUS-RTU |
Distance Measurement Range | 7m |
Measurement Accuracy | ±3mm |
Resolution | 1mm |
Measurement Time | 1s |
Start-up Time | <3s |
2. Connector Definition
Four-core Cable Definition:
Pin No. | Color | Definition |
1 | Red | Power Positive |
2 | Blue | Power Ground |
3 | Brown | RS485_A(+) |
4 | Yellow | RS485_B(-) |
3. Installation Instructions
When installing the level meter, the beam of the level meter must be perpendicular to the measured surface. The surface to be measured should be as flat as possible. The radiation angle of the level meter is 12 degrees, and it measures a plane rather than a point. The readback data is the distance of the surface with the largest reflection area. If there are steps on the test surface, it is likely to cause errors in the measured data.
Refer to the cable description according to the actual goods.

4. 485 Communication Protocol
4.1 Basic Communication Settings
Parameter | Setting |
Baud Rate | 9600/115200 (default: 9600) |
Parity Bit | None |
Data Bits | 8 |
Stop Bits | 1 |
4.2 Communication Specifications
RS485: Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential signal, twisted pair is recommended.
Data Rule: The high bit of the data area is transmitted first.
CRC Check Rule: When the CRC result is placed in the message frame, the low byte comes first.
Supplementary Notes: The upper computer serial port number ranges from 1 to 20, facilitating communication with USB-to-serial cables extended by USB-HUB.
4.3 Protocol Example
Send: 01 (Address) 03 (Function Code) 00 01 (Starting Register Address: 01) 00 01 (Read 1 Data) D5 CA (CRC Check)
Receive: 01 (Address) 03 (Function Code) 02 (Number of Bytes Read) 00 01 (Empty Height: 1mm) XX XX (CRC Check)
5. Quick Start Commands
Measurement Item | Type | Content |
Empty Height | Command | 01 03 00 00 00 01 84 0A |
Response | 01 03 02 00 01 79 84 | |
Parameter Description | The returned result is 2 bytes, where 0x0001 is in hexadecimal, converted to decimal is 1, indicating 1 cm | |
Empty Height | Command | 01 03 00 01 00 01 D5 CA |
Response | 01 03 02 00 02 39 85 | |
Parameter Description | The returned result is 2 bytes, where 0x0002 is in hexadecimal, converted to decimal is 2, indicating 2 mm |
6. MODBUS Protocol - Read-Only Registers
Note: U16 = Unsigned 16-bit integer
No. | Register Address | Function | Unit | Remarks |
1 | 00H | Empty Height | cm | |
2 | 01H | Empty Height | mm | |
3 | 02H | Water Depth | cm | Default is 20 meters minus empty height; total height can be set |
4 | 03H | Water Depth | mm | Default is 20 meters minus empty height; total height can be set |
5 | 04H | Address | Default 0X01 | |
6 | 05H | Reserved | ||
7 | 06H | Start Distance | cm | |
8 | 07H | End Distance | cm | |
9 | 08H | Low Power Consumption Setting | 0x001: Low power consumption; 0x002: Non-low power consumption | |
10 | 09H | Baud Rate | 0x001: 9600; 0x002: 115200 | |
11 | 0AH | Reserved | Returns 0X0 | |
12 | 0BH | Calibration | 0x0000: 0; When setting a negative number, it is 32768 + the absolute value of the negative number to be set; When setting a positive number, set it directly. Unit: mm | |
13 | 0CH | Reserved | Returns 0 |