Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge
Radar water level gauge/Radar level gauge

Radar water level gauge/Radar level gauge

$500.00
Color:silvery white
Weight:2kg
measure distance:0~40M
voltage:12V
Quantity
Click to Buy
Click to consult
Detail

Radar level meters are widely used in water conservancy projects (reservoir and river level monitoring), municipal sewage treatment, industrial liquid storage tank level control, and environmental hydrological monitoring. With the characteristics of resistance to rain, fog, high and low temperatures, they can operate stably in complex and harsh environments, realizing accurate and real-time level data collection and transmission.

1. Operating Parameters

Parameter

Description

Supply Voltage

DC 7~28V

Current (12V Power Supply)

Average current is about 60mA (5—100mA) during normal operation

Operating Temperature

-40~85°C

Waterproof Rating

IP68

Transmission Frequency

24~25.8GHz

Communication Interface

RS-485

Communication Protocol

MODBUS-RTU

1.2 Measurement Parameters

Parameter

Description

Ranging Range

40m

Measurement Accuracy

±3mm

Resolution

3mm

Measurement Time

1s

Start-up Time

<3s

1.3 Wiring

The cable description shall be corresponding to the actual goods:

Four-core Cable:

Pin No.

Color

Definition

1

Red

Power Positive

2

Blue

Power Ground

3

Brown

RS485_A(+)

4

Yellow

RS485_B(-)

1.4 Communication Interface

1.4.1 RS485 Interface

The green cable is RS485A(+), and the yellow cable is RS485B(-). When communicating with RS485 interface, the basic settings are as follows:

Baud Rate

9600 (default)

Parity Bit

None

Data Bits

8

Stop Bits

1

2. 485 Communication Protocol

2.1 Detailed Protocol Specifications

2.1.1 Basic Communication Settings

9600/115200, 8, N, 1; (The upper computer serial port number ranges from 1 to 20 to facilitate communication with USB-to-serial cables extended by USB-HUB). RS485; (Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential, twisted pair; *Data Rules: The high bit of the data area comes first; *CRC Check Rule: When the CRC result is placed in the information frame, the low bit comes first).

2.1.2 Communication Example

Address Field: The valid address range of the slave (target address) is 1~247, supporting broadcast send-receive address 0xFF and broadcast receive-only address 0xFE. When using the broadcast address, ensure that only one sensor is connected; otherwise, it will cause data errors or hardware damage.

Function Field: Valid codes are 1~255. The ultrasonic flow meter supports 0x03, 0x06, and 0x10 function codes.

Data Field: The data field consists of multiple groups of such data—two hexadecimal numbers as a group, ranging from 00~FF.

CRC Check Code: After CRC generation, the low byte comes first and the high byte comes after.

T1, T2, T3, T4 represent the transmission time length of each byte, totaling four byte transmission delay times.

9600, 8, N, 1; (The upper computer serial port number ranges from 1 to 20 to facilitate communication with USB-to-serial cables extended by USB-HUB).

RS485; (Half-duplex communication, supporting one master and multiple slaves; two-wire system, differential, twisted pair;

Data Rules: The high bit of the data area comes first;

CRC Check Rule: When the CRC result is placed in the information frame, the low bit comes first.

2.1.2 Ultrasonic Flow Meter Register Variable Status Table

U16: Unsigned 16-bit integer

No.

Register Address

Function

Unit

Remarks

1

00H

Device Temperature, signed number, scale factor +100

0.01°C

Invalid

2

01H

Instantaneous Velocity

mm/s

For testing

3

02H

Average Velocity

mm/s

Customers should use this result

4

03H

Reserved



5

04H

Flow Direction


1: Downstream
2: Upstream

6

05H

Installation Angle, scale factor +100

0.01°

Angle with horizontal plane

7

06H

Device Voltage

mV

Device Voltage

8

07H

Jump Filter Status


1: Jump
0: Normal

9

08H

Instantaneous Flow Rate (m³/S)


Independent flow register, exists independently of the previous registers and is discontinuous

10

09H

Water Depth

cm


11

0AH

Midline Velocity

mm/S


12

0BH

Low Power Consumption Setting


0x001: Low power consumption;
0x002: Non-low power consumption

13

0CH

Baud Rate


0x001: 9600;
0x002: 115200

14

0DH

Gain Value


0x0000: Auto gain; others are set gain values

15

0EH

Time Domain Threshold



16

0FH

Frequency Domain Threshold



17

A0H

Address